Part number 173089-01 Revision C, April 2006 1900/65A General Purpose Equipment Monitor Field Wiring Diagrams 1900/65A Field Wiring Diagrams ii Copyright © 2005 Bently Nevada, LLC All Rights Reserved The information contained in this document is subject to change without notice The following are trademarks of Bently Nevada, LLC in the United States and other countries: ACM™, Actionable Information ® , Actionable Information to the Right People at the Right Time ® , ADRE , Asset Condition Management™, Asset Condition Monitoring™, Bently ALIGN™, Bently BALANCE ® , Bently DOCUVIEW™, Bently LUBE™, Bently PERFORMANCE™, Bently Nevada , CableLoc™, ClickLoc™, Data Manager , Decision Support SM , DemoNet™, Dynamic Data Manager ® , Engineer Assist™, FieldMonitor™, flexiTIM™, FluidLoc ® , Helping You Protect and Manage All Your Machinery , HydroScan , HydroView™, Key ∅® , Keyphasor ® , Machine Condition Manager™ 2000 , MachineLibrary™, Machine Manager™, MicroPROX ® , Move Data, Not People ® , Move Information, Not Data™, NSv™, Prime Spike™, PROXPAC ® , Proximitor ® , REBAM , RuleDesk™, SE™, Seismoprobe ® , Smart Monitor , Snapshot™, System 1™, System Extender™, TDXnet™, TDIXconnX™, TipLoc™, TorXimitor ® , Transient Data Manager ® , Trendmaster , TrimLoc™, Velomitor ® Bently Nevada’s orbit logo and other logos associated with the trademarks in bold above, are also all trademarks or registered trademarks of Bently Nevada in the United States and other countries The following ways of contacting Bently Nevada are provided for those times when you cannot contact your local Bently Nevada representative: Mailing Address 1631 Bently Parkway South Minden, NV 89423 USA Telephone 1 775 782 3611 1 800 227 5514 Fax 1 775 215 2873 Internet wwwbentlycom iii Additional Information Notice: This document does not contain information required to operate and maintain the 1900/65A Refer to the Following manuals for other required information 1900/65A Datasheet (173401-01) • Description • Features • Specifications • Ordering Options • Approvals • Accessories 1900/65A Manual (173400-01) • System Description • Receiving and Handling Instructions • Installation • Configuration • Maintenance • Troubleshooting 1900/65A Hazardous Area Approvals • Throughout this document where Division 2, Division 1, Zone 1, and Zone 0 are used the following agency approvals exist: North American: Ex/AEx nA [L] IIC Class 1 Div 2 Groups A,B,C,D T4 -20°C ≤ Ta ≤ 70°C Vn = 18 to 36 Vdc Imax = 1A per drawing 173089 European: II 3G Ex nA [nL] IIC T4 -20°C ≤ Ta ≤ 70°C Sira 06 ATEX 4053X IECEx SIR 060012X per drawing 173089 Notice: No changes to this document without authorization from approvals agencies